Loading
Loading
Review of Case Materials
Reviews records, documents, testimony, data, and other relevant materials and consults with counsel regarding technical issues related to the matter.
Provide Expert Analysis
Applies specialized knowledge and experience to evaluate the technical or professional issues involved.
Form Expert Opinions
Develops independent, supportable opinions based on the available evidence and relevant standards.
Prepare Expert Reports
Showing Results 0 of 0
A fenestration investigation can examine glazing, frames, gaskets, sealants, drainage openings, fasteners, hardware, perimeter joints, flashings, anchorage, and connections with surrounding construction. Shop drawings, product information, and installation details can be compared with field measurements and visible conditions to assess whether the installed assembly is consistent with its documented configuration. That comparison can also identify components, joints, drainage paths, or perimeter interfaces that warrant closer evaluation.
Field testing can evaluate air-leakage or water-penetration performance under defined test conditions and can help identify locations where air or water passes through the fenestration assembly or, when the procedure is appropriately configured, its perimeter. Results should be compared with staining, drainage paths, joint conditions, weather exposure, installation details, and other physical evidence. A detected test leak does not necessarily establish the original field leakage source because water can travel within frames or surrounding assemblies and different test procedures evaluate different portions of the installed system.
Perimeter sealants are intended to accommodate anticipated joint movement while maintaining adhesion to the adjoining substrates. Aging, unsuitable joint geometry, inadequate surface preparation, material incompatibility, or movement beyond the joint's capability can contribute to cracking, adhesive separation, or cohesive deterioration. The surrounding flashing, drainage, air-sealing, and perimeter details should also be examined because a deteriorated sealant joint may represent only one part of a broader fenestration-performance condition.
Even units of similar design can experience different wind and rain exposure, installation tolerances, frame movement, perimeter detailing, drainage conditions, repairs, or deterioration. When the units being compared are sufficiently similar in size, configuration, design, and operating condition, comparing affected and unaffected locations can help identify variables associated with the reported performance difference. Those comparisons should be evaluated with field measurements, installation details, exposure conditions, and testing rather than treated as proof of one cause by themselves.
Prepares clear, well-supported expert reports outlining methodology, analysis, findings, and opinions.
Provide Deposition Testimony
Explains findings and opinions under oath and responds to questioning during deposition testimony.
Testify in Court
Presents specialized findings and opinions clearly to judges, juries, arbitrators, or other decision-makers.